NYC 9/11 Public Portal Document
Fibers - NIOSH Sampling and Analytical Method 7400. Results were compared to the
OSHA PEL for asbestos fibers of 0.1 fibers per cubic centimeter of air.
• Ethanolamine - NIOSH Sampling and Analytical Method 2007. Results were compared to
the OSHA PEL for Ethanolamine of 3 parts per million.
Representative sampling was conducted on each floor within the NYCLD space.
Because there is reason to believe that the fibers generated by the WTC collapse were small
fibers, TEM analysis of air samples for asbestos was the analytical method used in this
assessment to determine whether asbestos was present in the air. TEM is the state of the art
analytical technique with the greatest analytical sensitivity to identify small asbestos fibers that
can be missed by other analytical techniques, including Phase Contrast Microscopy (PCM).
Biological sampling was conducted in the cellar and subcellar areas. These areas were the only
areas impacted by water intrusion as a result of power failure. Results of this sampling are
presented in Appendix C and under separate cover in the March 8, 2002 report entitled
“Microbiological Investigation of Subcellar and Cellar at 100 Church Street.”
Air sampling for fibers and ethanolamine (the active ingredient in the carpet mastic release
agent) was conducted during carpet removal activities. Sampling was conducted to determine if
carpet removal control procedures were effective in controlling potential exposures below United
States Occupational Safety and Health Administration (OSHA) permissible exposure limits
(PEL). Due to the quantity of data, the results of this sampling are presented under separate
cover in the April 2, 2002 report entitled “Environmental Monitoring for Carpet Removal at 100
Church Street.” Any results for fiber air sampling by PCM that exceeded the OSHA PEL or
New York City Department of Environmental (NYCDEP) clearance air standards for personal
and area samples, respectively, were further analyzed by TEM to determine if the fibers present
were asbestos.
All analytical work was performed by independent laboratories certified by the NYSDOH under
ELAP.
3.6 Outside Air Quality Data
9
CITY_21 MC100_014587230
NYC-WTC_000243817
OCR can misread numbers and units. Confirm readings against the page image before using them.