NYC 9/11 Public Portal Document
Mr. G. Foster Mills
New York City Law Department
April 9, 2002
Page 3
2.1 Personal Air Sampling
Asbestos
Personal air sampling for airborne fibers was based on procedures described by OSHA. This involves
placing a personal air-sampling pump on a worker throughout the duration of a work shift. An air sample
filter cassette was attached to the pump by a flexible plastic (tygon) tube and clipped to the collar of a
worker, i.e. the cassette was positioned inside the worker’s “breathing zone”. Air was drawn through the
cassette, thereby trapping airborne particles and fibers on the filter.
The cassettes were sent to a laboratory for analysis by PCM and the results compared to the OSHA PEL.
One hundred and eighty two (182) air samples were collected from the breathing zones of various
workers who removed the carpeting. These samples were collected throughout the 12-hour work shift and
were analyzed for airborne fibers using Phase Contrast Microscopy (PCM). All 182 samples were found
to be below the OSHA PEL of 0.1 fibers per cubic centimeter of air (f/cc). As a quality control measure,
five (5) of these samples were re-analyzed by Transmission Electron Microscopy (TEM), which differs
from PCM in that TEM can differentiate between asbestos and non-asbestos fibers. No asbestos was
detected in the five samples analyzed by TEM.
Seventy (70) samples were collected from workers for a 30-minute duration and were analyzed for
airborne fibers using PCM. All 70 samples were found to be below the OSHA STEL of 1.0 free. As a
quality control measure, two (2) of these samples were re-analyzed by TEM, and no asbestos fibers were
detected.
Ethanolamine
Personal air sampling for ethanolamine vapor was conducted by placing a personal air sampling pump on
a worker and drawing air through a filter cassette for the duration of the 12-hour work shift. The cassette
was sent to a laboratory for analysis and the results were compared to the OSHA PEL.
Sixty-six (66) were collected from the breathing zones of various workers who removed the carpeting. All
66 samples were below the analytical detection limit.
2.2 Area Air Sampling
Air samples were collected adjacent to the areas where the carpet removal was being performed. These
are known as “area” air samples. These samples differed from personal air samples in that the sample
Customer-Focused Solutions
NYC-WTC_000235442
OCR can misread numbers and units. Confirm readings against the page image before using them.