TRC had a Certified Industrial Hygienist (CIH) visually inspect the entire NYCLD space,
common spaces that NYCLD employees enter in the course of their work in the building, and
“hidden” spaces that serve the area, including the HVAC and other mechanical spaces. This
inspection included accessible areas of the HVAC system serving the NYCLD spaces. A
boroscope with a self-contained light source was utilized as needed to assist in the visual
inspection of the ductwork.
3.4 Dust Sampling and Analysis
TRC conducted wipe and microvacuum sampling of residual dust to confirm the effectiveness of
the response actions. The following identifies the sampling and analysis that was conducted
along with associated standards and guidelines:
• Asbestos - American Society for Testing and Materials (ASTM) Test Method D5756-95
Microvacuum Sampling and Indirect Analysis (Filter Sample Analysis) of Dust by
Transmission Electron Microscopy (TEM) for Asbestos Structure Number Concentration. A
post-cleaning individual sample target concentration of less than 10,000 structures per square
centimeter (str/cm^) and a geometric mean concentration of 1000 str/cnr was established for
this project.
Lead - United States Department of Housing and Urban Development (HUD) Wipe
Sampling Guidelines. A post-cleaning lead wipe target concentration of 40 micrograms per
square foot (ug/ft^) for occupied spaces and 400 ug/ft^ for non-occupied spaces was
established for this project.
• PCBs - United States Environmental Protection Agency (USEPA) Document EPA 560/5-85-
026 Verification of PCB Spill Cleanup by Sampling and Analysis. The USEPA clearance
criteria of 10 micrograms per 100 square centimeters was used for this proj ect.
• Total Particulates - Modified National Institute for Occupational Safety and Health (NIOSH)
Sampling and Analytical Method 0500. Dust loading inside computer equipment was
compared to non-impacted control concentrations.
Dioxin - USEPA Document EPA-Methods 8290 and 1668. No clearance concentrations are
established for surface dioxin concentrations. Therefore, TRC incorporated wipe data into a
site specific human health risk assessment.
• Biological - American Industrial Hygiene Association Sampling Guidelines. Data was
compared to New York City Department of Health (NYCDOH) guidelines.
7
CITY_21 MC100_014587228
NYC-WTC_000243815
OCR can misread numbers and units. Confirm readings against the page image before using them.