Air sample test report, July 1992

Machine-extracted title · confidence 28%

ASTM E 981–based air sample test with potency estimation and tracings.

NYC-WTC_000242944–000242949
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Anderson Laboratories InC> EFFECTS OF SMOKES AND OFFGASING

ASTM E-981, ESTIMATING SENSORY IRRITATION FROM INDOOR AIR POLLUTION AND OFFGASING PRODUCTS

GENERAL METHOD

Four mice are exposed for 15 minutes prior to exposure to clean air. This establishes normal or baseline breathing rates and patterns. It also acts as an internal control. The exposure chamber is an all glass chamber with four side tubes. The side tubes act as animal holding chambers where the mice are in a head only exposure with a latex sheet lightly around their necks. Breathing data is collected by air pressure transducers and sent to a 4 channel recorder and data logging computer system. The exposure begins when the mice are connected to the pollution source. This is typically a large gas sampling bag (120 liters) or a chamber that has a suspect source in the chamber. Exposure typically lasts 30 minutes for building air and 60 minutes for product evaluation. Exposure is typically followed by a recovery period of additional 15 minutes. TVOC and Carbon Dioxide when desired are measured downstream from the exposure chamber. Breathing data is printed out for each individual mouse as well as the average. Respiratory depression values are determined by comparing the average baseline breathing rates with maximum sustained depression during the exposure. The direct recordings of the breathing patterns are evaluated as to the occurrence of upper respiratory effects (sensory irritation) or deep lung effects (pulmonary irritation). The ASTM Method states that respiratory depression of greater than 12% is considered significant but slight. Respiratory depression greater than 20% is considered moderate. Levels greater than 50% are considered severe.

CONFIDENTIAL, CITY_21MC100_003423865 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000242949

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242949Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

Compare copies and versions →