Table R2d: Mineral components in Indoor settled dust of the comparison buildings.
Chemical How many times Minimum amount Maximum amount Average of
was it found detected detected detected values
(6 samples) (% by weight) (% by weight) (% by weight)
Components of concrete
a-Quartz 4 1.1 2.2 1.45
Calcite 3 0.03 0.9 0.44
Portlandite 3 0.05 0.08 0.07
Other building materials
Gypsum____________ 5 1.8 4.2 2.8
Mica 1 0.08 0.08
Halite I 0.04 I 0.4
Table R3: Summary of airborne fibers. Air samples were collected and analyzed by Phased Contrast
Microscopy for total fibers (NIOSH 7400). All samples with fiber counts greater than background levels
were reanalyzed to determine if those fibers were asbestos, MMVF or other material.
Building Area PCM Fibers a Asbestos in Asbestos MMVF in MMVF
(f/cc) dust (f/cc) Dust F/cc)
1 Residence 0.006 ND by PLM <0.001 b 20% 0.000162
2 Common 0.005 ND by PLM <0.001 b 27% 0.000255
19 Common Overloaded c ND <0.006 ND Not
Requested
24 Residence 0.005 ND <0.001 b 10% 0. 37
26 Common 0.004 ND <0.001 b 5% <0. BHffi!
26 Residence 0.012 ND <0.001 * ND ND **
® * f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers
seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of
air.
« ** Analysis was requested, lab worksheet was returned with ‘ND’; however, we have not yet
received the official lab report (expect 0.000037 <AS < 0.000047f/cc).
* The TEM method employed here, NIOSH 7402, counts fibers of the same size as those detected by PCM
analysis. Fibers reported here are greater than or equal to 5 microns in length and 0.25 microns in width.