I Jeanine Prudhomme - sampPlan^draft plan 25b.wpd

Background sites are not being designated in any zone because those sites that happen to be upwind during any given time period will supply background data. Particulate monitoring will focus on real-time monitors that produce data approximately every two hours, allow near-real time assessment of the situation around the area.

Data Quality and Quality Assurance A consolidated Quality Assurance Project Plan (QAPP) has not been developed for this project, largely because of time constraints associated with the emergency nature of the work, and because there are a number of significant quality assurance programs and activities underlying and incorporated into the work. Each monitoring organization included in this work has a long-standing Quality System (or equivalent) in place, documented in its Quality Management Plan (or equivalent), and supported by management’s philosophical and resource commitments to data quality. Each of those Quality Systems acknowledges the possibility that emergencies such as this will require monitoring activity without the normal complement of QA documentation, with the tacit assumption that the organization will do whatever is possible and practical to ensure that the environmental data collected will be appropriate for the intended use and will be documented to the best extent possible.

This current plan is substituting for a QAPP in most respects, by outlining the intended uses of the various data elements along with the various steps that are being taken to ensure the usefiilness of the data. Data objectives and data quality criteria have been selected to satisfy project objectives, which, in turn, have been determined by informal consensus among the health and monitoring professionals. Since timeliness of the reporting of results is a critical factor, some compromises have been needed, but the data are still expected to satisfy project needs.

As much as possible, standard monitoring methodologies are being utilized, consistent with any applicable standards, and with the monitoring activities following either Standard Operating Procedures (SOPs) or the manufacturer’s instructions. In addition, the same monitoring procedure is being utilized at each station (particularly within a given zone), and a single laboratory is being used to analyze all samples of a given type to ensure the consistency and I comparability of the resulting data. The representativeness of the collected samples is being ensured through the development of the monitoring network and the careful selection of the specific monitoring locations by experienced professionals. The parameters being measured were selected (informally) through the consensus of the monitoring organizations, utilizing available information about the disaster site and the circumstances. Duplicate samples are being collected at least daily from at least one site for most parameters to serve as a quality control check on the precision of the measurement process. In some cases, the use of collocated samplers of slightly different types (such as continuous instruments collocated with time integrated samplers) will provide the functional equivalent of duplicate samples.

NYC-WTC_000242020

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242020Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427190

Chain-of-custody for August 2005 ambient air monitoring at 130 Liberty Street deconstruction site, LMDC.

Similar indexed content

Compare copies and versions →