NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
NYC-WTC_000241970–000241980OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Ambient and Indoor Sampling for Public Health Evaluations for areas near WTC DRAFT ATSDR/DHAC Version 6, October 10, 2001
I. Introduction: Mio® This sampling protocol was developed to address settled surface dust and airborne i i il H materials that entered residential/commercial areas following the collapse of the World Trade Center (WTC) buildings. Another protocol is being developed to ensure that the ' potential for contaminants from ongoing cleanup activities are not being emitted from the work zone at levels of public health concern. The collapse of the WTC buildings resulted in a large number of residents and office workers being evacuated from their homes or places of work. Until DATE, residents were not allowed to re-enter their homes in south Battery Park City (from West Thames Street and south, west of Broadway) or north of Chambers Street up through Canal Street, west of Broadway. Currently areas south of Chambers Street and north of West Thames Street, west of Broadway remain restricted; however, it is anticipated that residents will soon be allowed to move back into their homes. To date, environmental sampling efforts have focused on rescue/recovery areas (occupational); some sampling of commercial buildings to ensure office worker safety; and ambient air sampling for asbestos in a number residential/commercial areas. Additional environmental sampling is necessary to ensure that residential and commercial areas are not adversely impacted by WTC collapse-related materials.
Surface dust and debris containing <1-4% asbestos has been found in lower Manhattan. Asbestos has been detected in personal air samples of “hot-zone” workers. In addition, low levels of asbestos have been detected in air samples collected on the “hot-zone” perimeter. Crystalline silica quartz has been detected in some of the 30 settled dust samples collected by NIOSH. Although most samples contained less than 5%, some samples contained from 15-20% crystalline silica quartz. Detectable levels of crystalline silica have not been found in the few personal air samples from the work site that have been analyzed to date.
Dust, bulk, and air samples (mostly on or near the work site), as well as surface runoff water, river sediment, and river water have been analyzed for other contaminants, including metals, volatile organic compounds (VOCs), PAHs, dioxins and PCBs. The low levels of these contaminants found do not indicate an immediate need to conduct widespread environmental testing for them.
Materials in airborne dust that may be of more immediate health concern-especially to residents who are returning to lower Manhattan-are those that may cause eye, nose, and throat irritation. Materials that can be inhaled or respired from airborne dust may cause respiratory irritation and may cause exacerbation of pre-existing problems such as asthma, emphysema, and cardiopulmonary disease. Analysis of residential surface and airborne dust, both indoors and outdoors, is necessary to determine 1) if residents are being exposed to materials that may be of public health concern; and 2) whether areas already cleaned (inside and outside
Page 1 of 11
NYC-WTC_000241970
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
14 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250606
DOH page showing page 1 of sampling protocol for WTC residential areas.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320050
Draft ATSDR/DHAC evaluation of ambient and indoor dust near WTC with asbestos data.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
14 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
14 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
14 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304431
Draft ATSDR/DHAC update on ambient environmental monitoring near WTC; area restrictions noted.
14 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
Similar indexed content
NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
Similar indexed content
NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
Similar indexed content
NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
Similar indexed content
NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similar indexed content