Z z O co NYC Response

s o o Asbestos Air Sampling Results for Staten Island Landfill Sampling Date and Time: 10/08/01 0700 to 10/08/01 2000

PCM by NIOSH 7400 TEM AHERA) U c CT o' KJ Sampling Sampling Sample f/mm^ f/cc Structures (#) S/mm’ S-f/cc* U O 00 Date Sample No. Location Volume Matrix 0.5p - 5p Sp 3. cn 03 o 10/08/01 02959 P Loc #1 720 Air <7.0 <0.004 1" 0 8.89 0.0048 o o 10/08/01 02960 P Loc #2 720 Air <7.0 <0.004 2" 0 17.78 0.0095 o 10/08/01 02961 P Loc #3 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 c 10/08/01 02962 381.2 <7.0 <0.007 0 3 P Loc #4 Air 0 <800 <0.0081 CD 02963 720 O 10/08/01 P Loc #5 Air <7.0 <0.004 0 0 <8.89 <0.0048 w 10/08/01 02964 P Loc #6 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 G ro 10/08/01 02965 P Loc #7 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 M 10/08/01 02966 P Loc #8 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 O 10/08/01 02967 S Loc #9 720 Air 14.65 0.008 6" 2" 71.11 0.0380 H 10/08/01 02968 S Loc #9A 196.7 Air 21.66 0.042 5" 3" 64 0.1253 H 10/08/01 02969 S Loc #9B 720 Air <7.0 <0.004 2" 0 16 0.0088 O 10/08/01 02970 S Loc #9C 720 Air <7.0 <0.004 1" 0 8 0.0043 3 10/08/01 565 31 02971 B Loc #13 Air 10.19 0.007 4" 1" 40 0.0273 O 10/08/01 02972 B Loc #14 562 Air <7.0 <0.005 4" 0 32 0.0219 H M 10/08/01 02973 W Loc# 11 545 Air <7.0 <0.005 0 0 <8 00 <0.0057 O o 10/08/01 02974 W Loc #12 633 Air 8.28 0.005 7" 4” 88 0.0535 H o s coc# 04611 '• Chrysotile; no other types of asbestos fibers were fou

a O M NS: Not sampled 3 a H Sample volume is below recommended limit of the method: > 'Structure (S) roughly equivalent to fiber (f) NA: not analyzed due to overloading of particulates 3 O NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 to Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA40CFR Part 763 (AHERA) Standard criteria: EPA40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm^ volume 1200 L, for 25 mm filter (TEM) w M 3 H ERT: 10/10/01 9:50 AM to o o co O H

s O O O I o o FK_10_07_01A on co o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241850Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →