For this sampling program, a minimum of 90% percent of the planned collection of individual samples for quantification must be obtained to achieve a satisfactory level of data completeness.

Validation of QC Samples for TEM

Re-Analysis. All re-analysis samples (either different or same) will be validated by comparing the raw data sheets prepared by each analyst. The following acceptance criteria will be used to identify cases where results are not within acceptable limits;

Measurement parameter Acceptance Criterion Number of fibers within each grid opening Must be the same Type of fiber Must be the same Fiber length 0.5 urn or 10% (whichever is less stringent) Fiber width 0.1 urn or 10% (whichever is less stringent)

Whenever an exception is identified, the sample will undergo validated analysis as described by NIST (1994), and the senior laboratory analyst will use the results of the validated analysis to determine the basis of the discrepancy, and will then take appropriate remedial action as needed (e.g., re-training in counting rules, quantification of size, identification of types, etc).

Re-Preparation. Re-preparation samples will be evaluated by binning the results from each of the two analyses into the following categories:

Fiber Size Fiber Type Code diam length Amphibole (L) Amosite (O) Chrysotile (urn) (urn) • (C) a aspect ratio < 5; 1 L-a 0-a C-a b <0.5 L-b 0-b C-b c >0.5 L-c 0-c C-c d <0.5 <5 L-d 0-d C-d e < 0.5 5-10 L-e 0-e C-e f. < 0.5 > 10 L-f O-f C-f

The results for bins L-d, L-e, and L-f must not be statistically different from each other at the 90% confidence interval, tested using the statistical procedure documented in Appendix F. No formal test will be performed for other bins, but it is expected that J

CONFIDENTIAL, CITY_21MC100_0 09513634 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241813

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241813Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →