NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 34 pages

Environmental monitoring draft for WTC collapse exposure, NYC

Machine-extracted title · confidence 44%

Draft NYC EH monitoring document on exposure to fibers after WTC collapse.

NYC-WTC_000407762–000407795
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Comparability: Data are comparable if collection techniques, measurement procedures, methods, and reporting units are equivalent for the samples within a sample set. These criteria allow comparison of data from different sources. Comparable data will be obtained by specifying standard units for physical measurements and standard procedures for sample collection, processing, and analysis. These requirements are specified in the attached SOPs for sample analysis procedures.

Completeness: Data are considered complete when a prescribed percentage of the total intended measurements and samples are obtained. Analytical completeness is defined as the percentage of valid analytical results requested. For this sampling program, a minimum of 90% percent of the planned collection of individual samples for quantification must be obtained to achieve a satisfactory level of data completeness.

Validation of OC Samples for TEM

Re-Analysis. All re-analysis samples (either different or same) will be validated by comparing the raw data sheets prepared by each analyst. The following acceptance criteria will be used to identify cases where results are not within acceptable limits:

Measurement parameter Acceptance Criterion

Number of fibers within each grid opening Must be the same Type of fiber Must be the same Fiber length 0.5 um or 10% (whichever is less stringent) Fiber width 0.1 um or 10% (whichever is less stringent)

Whenever an exception is identified, the sample will undergo validated analysis as described by NIST (1994), and the senior laboratory analyst will use the results of the validated analysis to determine the basis of the discrepancy, and will then take appropriate remedial action as needed (e.g., re-training in counting rules, quantification of size, identification of types, etc).

Re-Preparation. Re-preparation samples will be evaluated by binning the results from each of the two analyses into the following categories:

Fiber Size Fiber Type Code diam length Amphibole (L) Amosite (0) Chrysotile (um) (um) (C) a aspect ratio < 5;1 L-a 0-a C-a b <0.5 L-b 0-b C-b c >0.5 L-c 0-c C-c

NYC-WTC_000407792

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407792Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →