Allan Goldberg - Nyc-wtc sampling plan v2.doc Page 16 |

the main apartment as was used during the routine activity investigation (above). The sampling time will be the same for the stationary sampler as tor the personal sampler. To the extent feasible, pump How rates will be adjusted to approach or exceed the target volumes specified in Appendi.x G.

fn order to help quantify the impact of the activity (active cleaning) on asbesto.s levels in air, tlte stationary air monitor will also be used to collect a pre-activity and a post activity sample as wed a.s the sample during the activity. The sampling duration for these samples should be approximately 3 hours. An example sampling scheme is summarized below:

Minimum Target Volume” (L) Activity Example Clock lime ! I Personal Air Monitor Stationary Air Monitor

Pre-sampling 8:00-1 1:00 690

Active cleaning I 1:30-1:30 690 690

Post activity 2:00-5:00 690 a If feasible, collection of volumes greater than the minimum should be achieved since this will increase sensitivity.

The stationary air sample collected post activity will be analyzed using the AHERA method (USEP.A 1987). A property will be considered suitable for re-habitation if this sample complies with the AHERA standard (or a more stringent standard, as directed by the NYC Health Department). If the clearance sample fails this standard, either more clearance samples mav ne collected, or alternatively, the pre-activity sample may be analyzed. In this case, the residence will be considered suitable for re-habitation if the final clearance sample does not have a finer concentration higher than the pre-activity sample.

Immediately prior to initiation of the cleaning activities, a composite dust sample will be collected from the apartment in accord with SOP ASTM 5755-95. This sample is intended to provide a representative composite of the dust inside the apartment, especially in living areas. As noted above, if sweeping or dusting activities results in the generation of a pile of dust, a I' sample of this material will also be collected using the microvac technique in order to provide a I second sample to evaluate for fiber content.

If preliminary practice sessions reveal that active cleaning generates sufficient dust to be detectable by real-time aerosol monitors, then two such aerosol monitors will be used to quantify I I the level of dust particles in the air before, during, and after the cleaning activities. One will be !: located in close proximity to the stationary air monitor in the main living area of the apartment. I

and one will be located in close proximity to the cleaning activity. Real-time aerosol monitoring will not be used during Scenario 2 if trial runs indicate that no useful data will be collected.

NYC-WTC_000241760

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241760Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →