[jeanine Pru^omme - Nyc-^ plan v2.doc Page 18]

these pre- and post-activity samples will be selected to yield a volume that meets or exceeds the minimum target volume specified in Appendix G without causing filter overload.

Stationary Air Monitor in the Main Business or Apartment

The stationary air sampler will be located in the main living area of the apartment or work area of the business. These samples will serve to measure the impact of the simulated restoration on “passive” air exposure at locations remote from the simulated restoration. In addition, these samples will sen'e as "clearance” samples to establish when the apartment or business is suitable for re-occupation by the owner or resident. Samples will be collected before, during and for three sequential time periods after simulated restoration work is completed. Pump flow rates will be set to ensure that a minimum volume of at least 1,200 L will be collected during each 3-hour sampling period (eg., 7-8 L/min). Analysis of these samples will be done using the AHERA method (USEPA 1987). A property will be considered suitable for re-habitation if the final clearance sample complies with the AHERA standard or a more stringent standard, as directed by the NYC Department of Health. If the final clearance sample fails this standard, either more clearance samples may be collected, or alternatively, the pre-activity sample may be analyzed. In this case, the residence will be considered suitable for re-habitation if the final clearance sample does not have a fiber concentration higher than the pre-activity sample.

The following tables provides an example schedule summarizing the that will be collected for this scenario:

Work area Main living area Time Period Example Clock time

Type Min Vol (L) Type Min Vol (L)

Pre-sampling 8:00AM-l 1:00AM Fixed ■ 1200 Fixed 1200

Simulated restoration 11:00 AM-12:00PM Personal 14 Fixed 400

Post activity 1 12:00PM-3:00PM Fixed 1200 Fixed 1200 Post activity 2 3:00PM-6:00PM Fixed 1200 Fixed 1200

Post Activity 3 6:00 PM-9:00 PM Fixed 1200 Fixed 1200

Dust Monitors

In addition to sampling for asbestos, two real-time aerosol monitors will be used to quantify the level of dust particles in the air before, during, and after the simulated restoration activities. One aerosol monitor will be located in close proximity to the stationary air monitor, and the other will be located in the enclosed area where the simulated restoration is occurring.

NYC-WTC_000241998

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241998Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →