Asbestos TEM analysis, New Stuyvesant HS, 09/21/01

Machine-extracted title · confidence 43%

TEM asbestos analysis results for New Stuyvesant HS, Sep 21, 2001.

NYC-WTC_000241250
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 New York City Board of Education Approved N.Y. State ELAP #10873 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 09/21/01 ASBESTOS FIBER /ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CTEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 33, 1987

Sample Identification Analysis Parameters

Project/Site: New StuwesanC H-S 345 Chainb€rsSt.NY,^^ TEM Sample No.: 5543 59293 11th Floor Mechanical Space Date Received; 09/237^ Grid Openings Analyzed: __ 4

Project Sample No.: NSHS-lLMS-9/21-07 Average Grid Opening; 106.00 um

Air Volume; 1820 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity ; Effective Area :385 mni2 0.0047 S/CC

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ;>=5um Str-uict/mm2 Struct/cc nom/ni3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 c 0.0 0.0000 0

Ambiguous 0 0 0 D 0 c c.o 0.0000 0

Total asbestos (includes ambiguous structures) 0 c 0.. 0 0.0000 0 Non-Asbestos 0 0 0 0 0 c C.0 0 .0000 N/A

No Identification 0 0 0 0 0 c 0.0 0.0000 N/A

Totals '(All Structures) 0 C 0.0 C . 0000 N/A

The estimated uncertainty of Chis analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003433339 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241250

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241250Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270598

TEM asbestos fiber analysis report for New York City building site; AHERA method, 10/20/01.

Similar indexed content

NYC-WTC_000340298

TEM analysis with SAED/EDS for AHERA method, project site at H.S., 10/04/01

Similar indexed content

Compare copies and versions →