NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant HS, 05/21/01

Machine-extracted title · confidence 43%

TEM asbestos analysis results for New Stuyvesant HS, May 2001.

NYC-WTC_000241248
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

New York City Board of Education Approved N.Y. State ELAP #10875 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 11S7 Long Island City, NY 11101 Report Date: 05/21/01

ASBESTOS FIBER ^kNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY ITEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 554S £9290 11th Floor Mechanical Space Date Received: 09/23701 Grid Openings Analysed:__4

Project Sample No.: NSHS-llMS-9/21-04 Average Grid Opening: 1'0 6.00 um

Air Volume : 1820 1hters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diain.. Pore Size: 0.45 um Analytical Sensitivity :22^2,s/mm2 Effective Area :385 mrr^ 0.004^ s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/mS

Chrysotile Asbestos 0 0 0 0 0 0 0, 0 a.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0

Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0. 0 0.0000 N/A

Totals (All Structures) 0 0 0. 0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003433337 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241248

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241248Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000241249

TEM asbestos analysis with SAED/EDS for New Stuyvesant HS, Sep 21, 2001.

Similar indexed content

NYC-WTC_000293311

TEM asbestos fiber analysis for New Stuyvesant High School, received 09/21/01.

Similar indexed content

NYC-WTC_000293317

TEM asbestos fiber analysis for New Stuyvesant High School, received 09/21/01.

Similar indexed content

NYC-WTC_000293321

TEM asbestos fiber analysis for New Stuyvesant High School, received 09/21/01.

Similar indexed content

NYC-WTC_000270593

TEM-based asbestos analysis with SAED/EDS for air samples at New Stuyvesant High School.

Similar indexed content

Compare copies and versions →