NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling report, silica, Stuyvesant HS, Dec 2001

Machine-extracted title · confidence 44%

ATC air sampling report for silica-containing dust at Stuyvesant High School, Dec 2001.

NYC-WTC_000241235–000241236
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

January 28, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Silica Dust Stuyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for silica-containmg dust conducted on December 10, 2001 and January 4 and 9, 2002 at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to the parents’ association.

Scope of Work

On each day, ATC collected twelve (12) samples for respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. Eleven (11) samples were collected indoors and one (I) was collected outdoors. The samples, plus one blank filter for each day, were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. Analysis for silica was performed by x-ray diffraction according to NIOSH Method 7500. Copies of the analytical reports are attached.

The sampling locations were:

December 7: l” floor hallway Main Entrance, 2”'' floor hallway, 2““* floor hallway by Room C232, 3'^ floor hallway. Pool, Auditorium, 3rd floor Gymnasium, Cafeteria, 5th floor Room 501 East, Room 402 South, Room 351 North, outdoors (North).

January 4: 1st floor lobby Main Entrance, I* floor hallway by Custodian Office (West), 2”** floor lobby, Pool, Auditorium, 3rd floor Gymnasium, Dining Room 5*’’ floor, Room 513 South, Room 638 North, Room 701 East, 10* floor hallway center, outdoors (entrance).

January 9: 1st floor lobby. Room 129 South, 2"“’floor lobby. Pool, Auditorium, Room 260 East, 3'“* floor Gymnasium, Dining Room 5* floor, 8* floor hallway by Room 815, 9* floor hallway by Room 911, Room 1006 North, outdoors (North),

CONFIDENTIAL, CITY_21MC100_003433196 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241235

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241235Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238317

Letter report from ATC Associates detailing silica dust air sampling conducted at Stuyvesant High School in late 2001 and early 2002.

Similar indexed content

NYC-WTC_000238328

Formal letter reporting results of respirable dust sampling conducted at Stuyvesant High School in January 2002.

Similar indexed content

Compare copies and versions →