NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling for silica, Stuyvesant HS, Feb 2002

Machine-extracted title · confidence 55%

ATC Associates letter report of silica air sampling conducted January 17 and 23, 2002 at Stuyvesant High School.

NYC-WTC_000241174–000241175
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

February 7, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Silica Stuyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica- containing dust conducted on January 17 and 23, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to the parents’ association.

ATC collected twelve (12) samples on each day for respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. One (1) outdoor sample and eleven (11) indoor samples were collected per day. The samples, plus blanks, were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. Analysis was perfonned by x-ray diffraction according to OSHA Method 142. Copies of the analytical reports are attached.

Silica was found above the limits of detection in three of the samples collected on January 17*. Sample S5, collected in the 2'“* floor Lobby, contained 0.0123 milligrams of silica per cubic meter of air (mg/m’). The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) for silica-containing dust is based on the percent of quartz (SiO2) found in the dust, the higher the percentage of quartz, the lower the PEL. The formula for calculating the PEL is found in 29 CFR 1910.1000, Table Z-3. The formula is:

lOmg/m^ %SiO2 + 2

The amount of quartz in this sample was <20%, therefore the PEL for this dust would be:

lOmg/m^ 0.455 mg/m’ 20-F 2

The silica concentration in this sample was 0.0123 mg/mg^, which is 2.7% of the calculated PEL.

CONFIDENTIAL, CITY_21MC100_003433113 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241174

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241174Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238328

Formal letter reporting results of respirable dust sampling conducted at Stuyvesant High School in January 2002.

Similar indexed content

NYC-WTC_000175070

ATC Associates report on air sampling for silica-containing dust conducted at Stuyvesant High School on February 6, 2002.

Similar indexed content

Compare copies and versions →