Pace Analytical Services. Inc. 1700 EIrp Street Suite 200 ’aceAnalyticar Minneapolis. MfJ 55414 Pnone: 612.607.1700 wm.pacelabs.com 612.607.64^14 TABLE 5. 2,3,7,,8-TCDD Equivalency Factors (TEFs) for the Polychlorinated Dibenzo-p-dioxins and Dibenzofurans

: I Number Compoundfs) TEF ------------ 1 2,3,7,8-TCDD 1.00 2 1,2,3,7,8-PeCDD 0.50 3 1,2,3,6,7,8-HxCDD 0.1 4 1,2,3,7,8,9-HxCDD 0.1 E5 1,2,3,4,7,8-HxCDD 0.1 €5 1,2,3,4,6,7,8-HpCDD 0.01 13 7;- OCDD 0.001 8 * Total - TCDD 0 * Total - PeCDD 0.0 9 0.0 10 * Total - HxCDD 0.0 g 11 * Total - HpCDD 0.0

12 2,3,7,8-TCDF 0.10 13 1,2,3,7,8-PeCDF 0.05 14 2,3,4,7,8-PeCDF 0.5 15 1,2,3,6,7,8-HxCDF 0.1 16 1,2,3,7,8,9-HxCDF 0.1 17 1,2,3,4,7,8-HxCDF 0.1 18 2,3,4,6,7,8-HxCDF 0.1 19 1,2,3,4,6,7,8-HpCDF 0.01 20 1,2,3,4,7,8,9-HpCDF 0.01 21 OCDF 0.001 22 * Total - TCDF 0.0 23 * Total - PeCDF 0.0 24 * Total - HxCDF 0.0 25 * Total - HpCDF 0.0

*Excluding the 2,3,7,8-SLibstituted congeners.

Reference: 1989ITEFs

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc,

CONFIDENTIAL, CITY_21MC1OO_OO343283O SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240927

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240927Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000240837

Series of Pace Analytical lab pages including C/F levels; NYC-WTC dataset.

Similar indexed content

Compare copies and versions →