NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

PACE Analytical labor report: 12 pages

Machine-extracted title · confidence 60%

12-page Pace Analytical report; adheres to NELAC standards.

NYC-WTC_000309898–000309901
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ^aceAnalyticar Minneapolis. Ml\l 55414 , Phone 612 607 1700 www.pacelabs. com Fax 612 607 6444 TABLE 1. 2,3,7,8-TCDD Equivalency Factors (TEFs) for the Polychlorinated Dibenzo-p-dioxins and Dibenzofurans

Number Compound(s) - TEF

1 2,3,7,8-TCDD 1.00 2 1,2,3,7,8-PeCDD 0.50 3 1,2,3,6,7,8-HxCDD 0.1 4 1,2,3,7,8,9-HxCDD 0.1 5 1,2,3,4,7,8-HxCDD 0.1 6 1,2,3,4,6,7,8-HpCDD 0.01 7 OCDD 0.001 8 * Total - TCDD 0.0 9 * Total - PeCDD 0.0 10 * Total - HxCDD 0.0 n * Total - HpCDD 0.0

12 2,3,7,8-TCDF 0.10 13 1,2,3,7,8-PeCDF 0.05 14 2,3,4,7,8-PeCDF 0.5 15 1,2,3,6,7,8-HxCDF 0.1 16 1,2,3,7,8,9-HxCDF 0.1 17 1,2,3,4,7,8-HxCDF 0.1 18 2,3,4,6,7,8-HxCDF 0.1 19 1,2,3,4,6,7,8-HpCDF 0.01 20 1,2,3,4,7,8,9-HpCDF 0.01 21 OCDF 0.001 22 * Total - TCDF 0.0 23 * Total - PeCDF 0.0 24 * Total - HxCDF 0.0 25 * Total - HpCDF 0.0

J * Excluding the 2,3,7,8-substituted congeners.

Reference: 1989ITEFs

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. X* “Co,.

/hdaci CITY_21MC100_003042985

NYC-WTC_000309901

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000309901Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000309888

Laboratory analysis report package from Pace Analytical for project samples.

Similar indexed content

Compare copies and versions →