NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 16 pages

Analytical laboratory reports: PCDDs & PCDFs, NYC-WTC

Machine-extracted title · confidence 27%

Attachment page of confidential PCDD/PCDF lab reports for NYC-WTC chain.

NYC-WTC_000240874–000240889
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 E!m Street. Suite 200 ^J^aceAnalyticar Minneapciis, MN 55414 Phone: S12.607.1700 wvrw.pacela.tis.com REPORT OF: CHEMICAL ANALYSES Fsx: 612.SD7.6444

PROJECT: PCDD/PCDF ANALYSES DATE: February 12, 2002

PAGE: 5 REPORT NO: 02-1053263

PCDD/PCDF Quantification and Calculations (Cont.) Each pair of ion mass peaks in the selected-ion-current chromatograms was evaluated manually to determine if it met the criteria for a PCDD or PCDF isomer. Areas of all peaks exhibiting correct ion ratios, having retention times within the correct windows, and having areas corresponding to concentrations in the range covered by the initial calibration were then summed for calculations of total congener concentrations. The toxic equivalence of each sample was calculated using the factors listed in '"able 5.

A limit of detection (LOD) based on producing a signal that is 2.5 times the noise level, was calculated for each undetected 2,3,7,8-substituted isomer of any tetra through octa chlorinated congener class. The noise heights used to calculate the detection limits were measured at the retention time of the specific isomer. The formula used for calculating the LOD is:

Hn X Qis X 2.5 LOD = His X W X Rf where:

LOD Single isomer limit of detection Hn Sum of noise heights at native isomer retention time Qis Quant ty of labeled internal standard His Sum of peak heights for labeled internal standard W Sample amount Rf Response factor

The recovery of the 2,3,7,8-TCDD-^’Cl4 enrichment efficiency standard and each --labeled internal standard, relative to either 1,2,3,4-TCDD-’'^Ci2 or 1,2,3,7,8,9-HxCDD-’^Ci2, was calculated using the following equation:

Ais X Qrs X 1 00% %R = Rfr X Ars x Qis ;■? where:

,,, %R = Percent recovery of labeled internal standard Ais = Sum of integrated areas of labeled internal standard Qrs = Quantity cf recovery standard Ars = Sum of integrated areas of recovery standard Rfr = Response factor of the specific labeled internal standard relative to the recovery standard Qis = Quantity of the labeled internal standard congener added to the sample

REPORT OF LABORATORY ANALYSIS This report shall net be reproduced, except in full. without the written consent of Pace Analytical Services. Inc.

/nebci CONFIDENTIAL, CITY_21MC100_003432767 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240880

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240880Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000312350

Attachment with analytical lab report for CITY_21MC100_003046195 and related identifiers.

Similar indexed content

Compare copies and versions →