Method 8290 analysis, ATC/ATC sample, 2002

Machine-extracted title · confidence 56%

From Pace/ATC: Method 8290; analysis results for wipe sample; ATC-0130-STY-DX1.

NYC-WTC_000240860–000240863
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FEB-21-02 15:44 FROM-PACE ANALYTICAL B12-BD7-6444 T-B2' P.03/05 F-D46 1700 Eirn Street - Suite 200 Minneapolis, MN 55414

Analytical Method 8290 Analysis Results Tar 612.607-1700 Fsx: 612- 607-6444

i Client - ATC Client's Sample ID ATC-0130-STY-DX2 Lab Sample? ID 103302741 Filename F20219B_07 Injected By BAL Total Amount Extracted 1 m2 Matrix WIPE % Moisture NA Dilution NA Dry Weight Extracted NA Collected 01/30/2002 I CAL Date 01/24/2002 Received 02/04/2002 CCal Filenam«(s) F20219B 01 &F2O219B_1G Extracted 02/15/2002 Method Blank ID BLANK-1468 Analyzed 02/20/2002 01:01 Native Cone EMPC LRL Internal ng's Percent Isomers ng/in2 ng/m2 ng/m2 Standards Added Recovery

2,3,7,8.TCDF ND — 0.00200 2,3,7,8-TCDF-13C 2.00 70 Total TCDF- ND ...... 0.00200 2.3,7.8-TCDD-13C 2.00 70 1,2,3,7,8-PeCDF-13C 2.00 79 2.3.7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 77 Total TCDD ND 0.00200 1,2,3,7,8-PeCDD-13C 2.00 71 1,2,3,4.7.8-HxCDF-13C 2.00 106 1,2,3.7.8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 78 2,3.4.7,8-PeCDF ND 0.01000 2,3,4,6,7.8-HxCDF-13C 2.00 92 Total PeCDF ND 0.01000 1,2.3,7,8,9-HxCDF-13C 2.00 89 1,2,3.4,7,8-HxCDD-13C 2.00 93 1,2,3,7.8-PdCDD ND 0.01000 1,2,3,6,7,8-HxCDD-l3C 2.00 90 Total PsCDD ND 0.01000 1,2,3,4,8,7,8-HpCDF-13C 2.00 81 1,2.3,4,7,S,9-HpCDF-13C 2.00 69 1.2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6.7.8-HpCDD-13C 2.00 76 1,2,3,6.7,8-HxCDF ND 0.01000 OCDD-13C 4.00 55 2,3,4,6,7,8-H:<CDF ND 0,01000 1,2.3,7,8.9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA Total HxCDF ND 0.01000 1.2,3,7.a.9-HxCDD-13C 2.00 NA

1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 71 1,2,3,6,7,8-HxCDD ND 0.01000 1,2,3.7,8,9»H:«CDD ND 0.01000 Total HxCDD ND 0.01000

1,2,3,4,6,7.8-HpCDF ND 0.01000 Total 2.3,7,8-TCDD 1.2.3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000039 ng/m2 Total HpCDF ND 0,01000 (Using ITE Factors)

1,2,3,4,6,7,8-HpCDD ND 0-01000 Total HpCDD ND 0.01000

OCDF ND 0.02000 OCDD 0.039 0.02000 BJ

LRU = Lower Reporting Limit Cono = Concanlration (Totalis include 2.3,7,e-substituted iiiomers) 1 = IntsrfarencB EMPCI Estirna wc MaxInriLim Possible Concentration E PCDE Interference A =: Detection Limit ttased on signal-to-noise measurement S = Saturated signal J =: ConoentraticD detected is below the calibration range ND = Not Detected B = Less Thar 10 times higher than method blank level NA = Not Applicable P :: Recovery oiitelde of ta rget range NC = Not Calculated Kn = Value obtained from additional analysis * = See Discussion Report No.... 02-1053714

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace,Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC100_003432746 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240861

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240861Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →