NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

ATC report, wipe samples, M477, May 2002

Machine-extracted title · confidence 26%

Cover memo reporting wipe-sample results for PCBs/PCDDs/PCDFs at a school site.

NYC-WTC_000240710–000240712
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan May 2,2002 Wipe Samples for Dioxins Page 2 Stuwesant Hieh School (M4771 ATC Project No. 15-19125-0246

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2,3, 7, 8 tetrachloro-dibenzo-p-dioxin (2,3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. A copy of the laboratory analysis report is attached. The results are shown in the following table.

DIOXIN WIPE SAMPLE RESULTS 2,3,7,8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m^) __________________ March 15,2002______________

1 Floor Lobby 0. EESH49 Main Entrance / DXl 2^® Floor Lobby 0.00028 Bridge Entrance /DX2 HVAC#II/DX3 0.0015

DIOXIN WIPE SAMPLE RESULTS 2,3,7,8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m^) ________________ March 20,2002_______________________

1®^ Floor Lobby 0.000032 Main Entrance / DXl 2^ Floor Lobby 0.0025 Bridge Entrance /DX2 HVAC#I/DX3 0.0017

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^).

On 3/15/02, the concentrations on indoor surfaces ranged from 0.000049 to 0.0015 nanograms per square meter (ng/m^). On 3/20/02, the concentrations on indoor surfaces ranged from 0.000032 to 0.0017 nanograms per square meter (ng/m^). The levels found in all of these samples are below the NYSDOH guideline of 25 ng/m^.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in this sample was deposited. Dioxin samples were not collected from these locations prior to November 8, 2001, and therefore a background sample is not available for comparison purposes.

CONFIDENTIAL, CITY_21MC100_003432545 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240711

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240711Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000400874

ATC report for wipe-samples of dioxins; St. High School; March 2002.

Similar indexed content

Compare copies and versions →