NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 22, 2002
Wipe Samples for Dioxins Page 2
Stuyvesant High School (M4771 ATC Project No. 15-19125-0246
Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer
were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by
multiplying by an established equivalency factor. This provides a single value (in nanograms)
for the analytical results for each sample. A copy of the laboratory analysis report is attached.
The results are shown in the following table.
DIOXIN WIPE SAMPLE RESULTS
2,3,7,8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m2)
April 17, 2002
LOCATION /SAMPLE ID DIOXIN CONCENTRATION
1^^ Floor Lobby 0.00044
Main Entrance / DXl
2’^° Floor Lobby 0.000039
Bridge Entrance /DX2
HVAC # 1/ DX3 0.0013
April 24,2002
LOCATION /SAMPLE ID DIOXIN CONCENTRATION
Floor Lobby 0.0067
Main Entrance / DXl
2’"° Floor Lobby 0.00092
Bridge Entrance /DX2
HVAC # II/ DX3 0.033
The New York State Department of Health (NYSDOH) established guidelines for dioxin for the
re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH
guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^).
On 4/17/02, the concentrations on indoor surfaces ranged from 0.000039 to 0.0013 nanograms
per square meter (ng/m^). On 4/24/02, the concentrations on indoor surfaces ranged from
0.00092 to 0.033 nanograms per square meter (ng/m^). The levels found in all of these samples
are below the NYSDOH guideline of 25 ng/m^.
It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in this sample
was deposited. Dioxin samples were not collected from these locations prior to November 8,
2001, and therefore a background sample is not available for comparison purposes.
CONFIDENTIAL, CITY_21MC100_003432631
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175717