NYC 9/11 Public Portal Document
I ■|r
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis. MN 55414
^ce Analytical' Tel: 612-607-1700
Far 612- 607-6444
Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0214-STY-DX2
Lab Sample ID 103331906
Filename U20306A_10
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/14/2002
ICALDate 03/05/2002 Received 02/18/2002
CCal Filename(s) U20305B_16&U20306A 17 Extracted 02/28/2002
Method Blank ID BLANK-1489 Analyzed 03/06/2002 22:30
Native Cone EMPC LRL Internal ng's Percent
isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND ---- 0.00200 2,3,7,8-TCDF-13C 2.00 62
Total TCDF ND ---- 0.00200 2,3,7.8-TCDD-13C 2.00 59
1,2.3,7,B-PeCDF-13C 2.00 68
2,3,7,8-TCDD ND 0.00260 A 2,3,4,7,8-PeCDF-13C 2.00 57
Total TCDD ND 0.00200 1,2.3,7,8-PeCDD-13C 2.00 63
1,2.3,4.7,8-HxCDF-13C 2.00 75
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 72
2,3.4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 71
Total PeCDF ND 0.01000 1,2,3.7,8,9-HxCDF-13C 2.00 70
1,2,3,4,7,8-HxCDD-13C 2.00 73
1,2,3.7,8-PeCDD ND - 0.01000 1,2,3,6,7.8-HxCDD-13C 2.00 65
Total PeCDD ND - 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 75
1,2,3,4,7.8,9-HpCDF-13C 2.00 74
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 73
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 59
2,3,4,6,7,8-HxCDF ND' 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3.4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1.2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3.7,8-TCDD-37CI4 0.20 66
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000064 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD 0.064 0.02000 BJ
LRL = Lower Reporting Limit
Cone » Concentration (Totals include 2,3,7,S-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E s PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA > Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn « Value obtained from additional analysis * = See Discussion
Report No.... 02-1054212
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Anaivtical Services. Inc.
CONFIDENTIAL, CITY_21MC100_003432366
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240547
OCR can misread numbers and units. Confirm readings against the page image before using them.