NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan January 29, 2002
Air Sampling for Metals & Mercury Vapor Page 2
Stuyvesant HichSchool______________ ATC Project No. 15-19125-0246
The established regulatory values for metals are intended for industrial workplace exposures and
are not generally applicable to office/school settings. There are no standards for these metals in
indoor air in non-industrial situations.
The Environmental Protection Agency has set a screening level for hexavalent Cr (the more toxic
form) of 0.6 micrograms per cubic meter of air (0.6 ug/m^). These above samples were analyzed
for total Cr (trivalent and hexavalent). The EPA level is based on continuous exposure to
hexavalent chromium for one year.
The EPA has no standard for Hg in ambient air.
Results
Metals
The levels of airborne metals did not exceed the limits of detection in any of the samples except
for Cr as follows:
Sample number ATC-01213-STY- Ml (obtained from 1’“ floor main lobby) was reported to be
0.000306 Blank corrected 0.000280 mg/m^.
Sample number ATC-01213-STY- M4 (blank) was reported to be 0.026 micrograms per filter.
The result of the blank indicates that Cr is a contaminant on the field blank.
All Cr levels were below the EPA level of 0.6 ug/m^.
Mercury
Mercury (Hg) was not detected in any of the samples at a level greater than in the blank..
ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call
me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_003432347
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240527
OCR can misread numbers and units. Confirm readings against the page image before using them.