104 East 25th Street New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

January 9, 2002

Mr. Bernard P. Orlan Director. Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Air Samples for Polychlorinated Biphenyls High School for Leadership & Public Service (M894) 90 Triraity Place New York, NY 10006 ATC Project No. 15-19125-0290

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of air samples for polychlorinated biphenyls (PCBs) collected on December 30, 2001, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination m tlie school building..

SCOPE OF WORK

Tenzin Namgyal and Wagdi Abdelsliahid, Industrial Hygienists of ATC’s New York City office, collected the samples.

The PCB samples were collected using glass fiber filters and Florisil® tubes connected in series to battery-powered sampling pumps set at a flow rate of 0.2 liters per minute (1pm). Tlie sampling time was ten (10) hours. The samples were analyzed by PSC Analytical Services, Inc. (PSC), an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed according to NIOSH Method 5503 (gas chromatography/electron capture detector). A copy of the laboratory report is provided in the Attachment.

The sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

SAMPLING RESULTS

ATC submitted nine (9) samples for PCBs to PSC for analysis. One blank was also submitted. Each sample was analyzed for seven (7) PCBs with different chlorine content. Samples were collected from (2) outdoor and seven (7) indoor locations.

CONFIDENTIAL, CITY_21MC100_003432216 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240379

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240379Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000310791

Air sampling results for PAHs at High School of Economics & Finance (M833), Jan 22, 2002.

Similar indexed content

Compare copies and versions →