NYC 9/11 Public Portal Document
1 04 East 25th Street
.▼ATC
10th Floor
New York, New York
10010-2917
212.353.8280
Fax 212.353.8306
ASSOCIATES INC.
January 15, 2002
Mr. Bernard P. Orlan
Director, Environmental health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Wipe Samples for Metals
High School for Leadership & Public Service (894M)
ATC Project No. 15-19125-0290
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe
samples for metals collected on January 2, 2002, at the referenced location. The New
York City Board of Education (BOE) requested these samples to determine levels of
metals on various surfaces within the school building.
Scope of Work
ATC collected surface wipe samples from various surfaces for analysis of eleven metals.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York
City office, collected the samples. Eight samples were collected using Palintest(® dust
wipes. The area of each sample was one square foot (1 ft^).
The samples, plus one blank, were sent to PSC Analytical Services, Inc., an American
Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was
performed by NIOSH Method 7300M. Each sample was analyzed for a panel of eleven
(11) metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt
(Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo),
nickel (Ni) ard zinc (Zn). A copy of the analytical report is attached.
ATC’s findings are based on the laboratory sample results and the conditions present in
the school at rhe time of the assessment.
The sampling was performed consistent with generally accepted industrial hygiene
practices. There were inherent limitations created by constraints of time, operational and
work practice variability, variations in contaminant concentrations, and sampling and
analytical accuracy. The results of the sampling represent conditions found on the dates
the samples were collected.
CONFIDENTIAL, CITY_21MC100_003432184
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240354