^ace Analytical__________ Method 8290 Analysis Results
Tel; 612-607-1700
Client - ATC
Client's Sample ID ATC-0222-M894-DX3
Lab Sample ID 103343307 L../-
Filename U2O312A_17
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracii^ NA Collected 02/22/2002
tCAL Date 03/12/2002 Received 02/25/2002
CCal Filename(s) U20312A_06 & U20312A_21 Extracted 03/04/2002
Method Blank ID BLANK-1495 Analyzed 03/12/2002 23:25
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND ---- 0.0029 A 2,3,7,8-TCDF-13C 2.00 79
Total TCDF ND ---- 0.0020 2,3,7,8-TCDD-13C 2.00 71
1,2,3.7,B-PeCDF-13C 2.00 73
2,3.7,8-TCDD ND 0.0047 A 2,3,4,7,8-P0CDF-13C 2.00 73
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 77
1.2.3.4,7.8-HxCDF-13C 2.00 89
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 74
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7.8-HxCDF-13C 2.00 77
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 82
1,2,3,4,7,8-HxCDD-13C 2.00 104
1,2,3.7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 75
Total PeCDD ND 0.0100 1,2,3,4,6,7.8-HpCDF-13C 2.00 89
1,2,3,4,7,8,9-HpCDF-13C 2.00 90
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 104
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4,00 84
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2,00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2,00 NA
1,2,3.4,7.8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0,20 68
1,2,3,6.7,8-HxCDD ND 0.0100
1,2.3.7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1.2,3.4,6.7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0,00059 ng/m2
Total HpCDF 0.017 0.0100 J (Using ITE Factors)
1.2,3.4,6,7,8-HpCDD 0,031 0.0100 BJ
Total HpCDD 0,058 0,0100 BJ
OCDF ---- 0.021 0.0200 I
OCDD 0.280 ---- 0.0200 B
LRL = Lower Reporting Limit
Cone = Concanuatian (Totals include 2,3,7,e-subslitirtsd isomers) I = interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detecton Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected it; below the calibration range NO = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside ol target range NC c Not Calculated
Nn = value obtained from acditional analysis * = see Discussion
Report No.... 02-1054412
REPORT OF LABORATORY ANALYSIS