Mr. Bernard P. Orlan January' 10, 2002 Air Sampling for Metals & Mercury Page 2 H.S. for Leadership & Pub. Sendee (894M) ATC Project No. 15-19125-0290

air sample: ri:sults - metals

Tire metals that were found above the limits of detection were chromium, copper, iron and zinc. The other seven metals were not detected. Table 1 lists the metals that were detected and their respective concenti'ation ranges. TABLE 1 DETECTED METAL CONCENTIL4TIONS (mg/m^ *) Metal Indoors

Chromium 0.000281 -0.000425 **BDL-0.000244

Copper BDL-0.00109 BDL-0.000214

Iron BDL-0.00776 BDL-0.0183

Zinc BDL - 0.000424 BDL

niiliigrams per cubic meter of air **BDL = Below Detection Limit

Chromium was. detected in six of the seven indoor samples and in the outdoor sample from the roof. Copper was also in six of seven indoor samples. Copper and iron were in the outdoor sample from the main entrance but neither were of these metals were in the roof sample. Iron was m three indoor samples. Zinc was detected in only one sample, indoors in the Library, it was not detected outdoors.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium in air of 0.6 ug/m'', this assumes a continuous exposure for one year. The samples here were analyzed for total chromium (trivalent and hexavalent). The concentrations are below the EPA level. The EPA has no published screening level or guideline for copper, iron or zinc.

MERCURY SAMPLE RESULTS

Air samples for mercury vapor were collected at the same locations as those for metals. No sample coniained mercujy at a concentration greater than that detected in the blank.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, Ini

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003431827 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240141

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240141Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297646

Letter report detailing December 29, 2001 air sampling for metals and mercury at the referenced school.

Similar indexed content

Compare copies and versions →