NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan June 4, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
iMETER
Respirable 65 micrograms per cubic
Particulates meter of air (pg/m^) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 M.g/ m3 24 hour average for children/sensitive
(PMa.s) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11* Street to East 33"^ Street. The
measurements were made from 5:47 A.M. to 4:34 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 10 pg/m^ to 25 pg/m^ with an
average of 18 pg/m^. The indoor concentrations ranged from 7 pg/m^ to 21
pg/m3 with an average of 14 pg/m’. None of the indoor or outdoor readings
were above the NPAAQS of 65 pg/m^ 24-hour average concentration of
particulate matter 2.5 micrometers or less in aerodynamic diameter or above
the USEPA recommended guideline for children and sensitive individuals of 40
pg/xn3.
These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, none of the indoor or outdoor readings were
above the NPAAQS of 65 pg/m3 24-hour average concentration of particulate
matter 2.5 micrometers or less in aerodynamic diameter or above the USEPA
recommended guideline for children and sensitive individuals of 40 pg/m3.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC ASSOCIATES INC.
Senior Project Manager
Attachment
CONFIDENTIAL, CITY_2IMCI0 0_003422799
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239905
OCR can misread numbers and units. Confirm readings against the page image before using them.