NYC 9/11 Public Portal Document
104 East 25th St, 10th
New York New York 10C
wwwatc enviro c(
212 353 82
Fax 212 353 83
ASSOCIATES INC
September 23, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Hydrocarbons
P. S. 124M
ATC Project No. 15-19125-0350
Dear Mr Orlan-
ATC Associates, Inc (ATC) is pleased to provide this report of the results of air
sampling for volatile hydrocarbon compounds conducted on September 12, 2002, at the
referenced school. The New York City Department of Education (DOE) requested this
sampling to verify that acceptable indoor air quality is being maintained.
Scope of Work
ATC collected three (3) samples for hydrocarbon compounds (HC) at specified locations.
Samples were collected for ten (10) hours using activated coconut shell charcoal tubes
connected to battery-powered sampling pumps at a flow rate of 0 2 liters per minute
Pumps were calibrated before and after each sampling period. One blank tube was also
submitted. The samples were sent to PSC Analytical Services, Inc., an American
Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was
performed by capillary gas chromatography/flame ionization detection (OSHA Method
7).
Tenzin Namgyal, Industrial Hygienist and Sonny Ramlal, Environmental Technician,
from ATC’s New York City office, conducted the sampling consistent with accepted
industrial hygiene practices. The results represent conditions on the day the samples were
collected.
Each sample was analyzed for a panel of sixteen (16) specific HC compounds. These
compounds were; pentane, acetone, methylene chloride, hexane, chloroform, methyl
chloroform, benzene, 1,2-dichloroethane, trichloroethylene, toluene, perchloroetyhylene
(tetrachloroethylene), chlorobenzene, ethylbenzene, styrene, cumene and xylenes In
addition, two non-identified peaks, total other A-hydrocarbons and total other B-
hydrocarbons, were reported. The A-hydrocarbons are those, such as gasoline or light
alcohols, with boiling points less than that of benzene (176°F) The B-hydrocarbons are
those, such as mineral spints or petroleum naphtha, with boiling points greater than that
of benzene. A copy of the analytical laboratory report is attached.