PCDD/PCDF determination report, PS 124M

Machine-extracted title · confidence 90%

Pace Analytical Services report detailing the determination of PCDD and PCDF levels in samples from P.S. 124M.

NYC-WTC_000239790–000239793
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ^ace Analytical' Minneapolis, MN 55414 Phone 6126071700 www.pacelabs.com Fax 6126076444 TABLE 1. 2,3,7,8-TCDD Equivalency Factors (TEFs) for the Polychlorinated Dibenzo-p-dioxins and Dibenzofurans

i Number Compound(s) TEF

1 2,3,7,8-TCDD 1.00 2 1,2,3,7,8-PeCDD 0.50 3 1,2,3,6,7,8-HxCDD 0.1 4 1,2,3,7,8,9-HxCDD 0.1 5 1,2,3,4,7,8-HxCDD 0.1 6 1,2,3,4,6,7,8-HpCDD 0.01 7 OCDD 0.001 . I ! 8 * Total - TCDD 0.0 9 * Total - PeCDD 0.0 10 * Total - HxCDD 0.0 11 * Total - HpCDD 0.0

12 2,3,7,8-TCDF 0.10 13 1,2,3,7,8-PeCDF 0.05 14 2,3,4,7,8-PeCDF 0.5 15 1,2,3,6,7,8-HxCDF 0.1 16 1,2,3,7,8,9-HxCDF 0.1 17 1,2,3,4,7,8-HxCDF 0.1 18 2,3,4,6,7,8-HxCDF 0.1 19 1,2,3,4,6,7,8-HpCDF 0.01 20 1,2,3,4,7,8,9-HpCDF 0.01 21 OCDF 0.001 22 * Total - TCDF 0.0 23 * Total - PeCDF 0.0 24 * Total - HxCDF 0.0 25 * Total - HpCDF 0.0

( *Excluding the 2,3,7,8-substituted congeners.

Reference: 1989 ITEFs

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc

CONFIDENTIAL, CITY_2IMCl00_003431438 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000239793

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000239793Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000239855

Laboratory report from Pace Analytical detailing the determination of PCDD/PCDF levels in samples analyzed in October 2002.

Similar indexed content

NYC-WTC_000309709

PCDD/PCDE determinations; 14-page Pace Analytical report for DOE project.

Similar indexed content

Compare copies and versions →