September 19, 2002
Mr Bernard P Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Mercury Vapor
P. S. 124M
ATC Project No. 15-19125-0350
Dear Mr Orlan
ATC Associates, Inc (ATC) is pleased to provide this report of the results of air sampling for
mercury (Hg) vapor conducted on September 12, 2002, at the referenced school The New York
City Department of Education (DOE) requested this sampling prior to the resumption of classes
to verify that acceptable indoor air quality is being maintained
Scope of Work
ATC collected three (3) samples for Hg vapor using Caruhte® (Hydrar) tubes connected to
battery-powered sampling pumps calibrated to collect 0 2 liters of air per minute The samples
were sent to PSC Analytical Services, Inc , an American Industrial Hygiene Association-
accredited laboratory in Reading, PA One blank tube was also submitted Analysis was
performed by means of a mercury vapor analyzer according to NIOSH Method 6009. A copy of
the analytical laboratory report is attached
Tenzin Namgyal, Industrial Hygienist, and Sonny Ramlal, Environmental Technician, from
ATC’s New York City office, conducted the sampling consistent with accepted industrial hygiene
practices The results represent the conditions on the day the samples were collected
The sampling locations were. T‘ floor Mam Lobby, 2"“* floor Hallway by Room 222 and 3'‘* floor
Hallway by Room 307
Results
Mercury (Hg) was detected in these samples at levels that were indistinguishable from that
detected in the blank
Mercury is a known trace contaminant of the Caruhte® sampling medium, the results suggest that
this IS the source of the mercury detected
The established regulatory value for mercury (0 Img/m^) is intended for industrial workplace
exposures and is not generally applicable to office/school settings There are no standards for
mercury m indoor air in non-industrial situations The EPA has no standard or guideline for
mercury vapor m ambient air