Mercury vapor air sampling results, PS 124M, Sep 2002

Machine-extracted title · confidence 95%

ATC Associates report on mercury vapor air sampling conducted at P.S. 124M for the NYC Department of Education.

NYC-WTC_000239759–000239760
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St, 10th Fl New York New York 10010 wwwatc-enviro com 212 353 8280 Fax 212 353 8306 ASSOCIATES INC

September 19, 2002

Mr Bernard P Orlan Director, Environmental Health and Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Mercury Vapor P. S. 124M ATC Project No. 15-19125-0350

Dear Mr Orlan

ATC Associates, Inc (ATC) is pleased to provide this report of the results of air sampling for mercury (Hg) vapor conducted on September 12, 2002, at the referenced school The New York City Department of Education (DOE) requested this sampling prior to the resumption of classes to verify that acceptable indoor air quality is being maintained

Scope of Work

ATC collected three (3) samples for Hg vapor using Caruhte® (Hydrar) tubes connected to battery-powered sampling pumps calibrated to collect 0 2 liters of air per minute The samples were sent to PSC Analytical Services, Inc , an American Industrial Hygiene Association- accredited laboratory in Reading, PA One blank tube was also submitted Analysis was performed by means of a mercury vapor analyzer according to NIOSH Method 6009. A copy of the analytical laboratory report is attached

Tenzin Namgyal, Industrial Hygienist, and Sonny Ramlal, Environmental Technician, from ATC’s New York City office, conducted the sampling consistent with accepted industrial hygiene practices The results represent the conditions on the day the samples were collected

The sampling locations were. T‘ floor Mam Lobby, 2"“* floor Hallway by Room 222 and 3'‘* floor Hallway by Room 307

Results

Mercury (Hg) was detected in these samples at levels that were indistinguishable from that detected in the blank

Mercury is a known trace contaminant of the Caruhte® sampling medium, the results suggest that this IS the source of the mercury detected

The established regulatory value for mercury (0 Img/m^) is intended for industrial workplace exposures and is not generally applicable to office/school settings There are no standards for mercury m indoor air in non-industrial situations The EPA has no standard or guideline for mercury vapor m ambient air

CONFIDENTIAL, CITY_21MC100_003431370 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000239759

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000239759Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →