NYC 9/11 Public Portal Document
104 East 25th St, 10th Fl
New York, New York 10010
wwwatc-enviro com
212 353 8280
Fax 212 353 8306
ASSOCIATES INC
September 20, 2002
Mr Bernard P Orlan
Director, Environmental Health & Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101-4008
Re: Air Sampling for Silica
P. S. 124M
ATC Project No. 15-19125-0350
Dear Mr Orlan
ATC Associates Inc (ATC) is pleased to provide this report of the results of air monitoring for
silica-contammg dust conducted on September 12, 2002, at the referenced school The New York
City Department of Education (DOE) requested this monitoring prior to the resumption of
classes to verify that acceptable indoor air qualify is being maintained
Scope of Work
ATC collected a total of three (3) samples (and one blank) for respirable dust using pre-weighed
37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable)
particles prior to deposition on the filters All of the samples were collected indoors The
samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association
accredited laboratory in Reading, PA Analysis for silica was performed by x-ray diffraction
according to OSHA Method 142 A copy of the analytical report is attached
Tenzin Namgyal, Industrial Hygienist and Sonny Ramlal, Environmental Technician of ATC’s
New York City office, collected the samples consistent with generally accepted industrial
hygiene practices As with all such sampling, there were inherent limitations created by
constraints of time, operational and work practice variability, variations m air contaminant
concentrations and sampling and analytical accuracy. The results of the sampling represent
conditions found on the dates the samples were collected
Results
Samples were obtained in the following locations, pt floor Mam Lobby, 21^^ floor hallway by
Room 222 and 3rd floor hallway by Room 307.
The results of all of the samples were below the detection limit for silica (<5 micrograms per
sample).