NYC 9/11 Public Portal Document
104 East 25th St, 10th Fl
New York, New York 10010
WWW atc-enviro com
212 353 8280
Fax 212 353 8306
associates INC
September 9, 2002
Mr Bernard? Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Metals
P.S. IM
ATC Project No. 15-19125-0340
Dear Mr Orlan
ATC Associates, Inc (ATC) is pleased to provide this letter report of air sampling for metals in 5
airborne dust on August 27, 2002, at the referenced school. The New York City Department of
Education (DOE) requested this sampling pnor to the resumption of classes to venfy that 1
acceptable indoor air quality is being maintained
Scope of Work
ATC collected three (3) samples for metals at specified locations Samples were collected for a
minimum of ten (10) hours using 37 mm mixed cellulose ester filter connected to battery-
powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and
after each sampling period All three samples were collected inside the building. Two blanks for
quality control were submitted. The additional blank was included to confirm the levels of any
trace contaminants in the filters The samples were sent to PSC Analytical Services, Inc., an
American Industrial Hygiene Association-accredited laboratory in Reading, PA Analysis was
performed by NIOSH Method 73 OOM Each sample was analyzed for a panel of twelve (12)
metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper
(Cu), iron (Fe), lead (Pb), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni)
and zinc (Zn) A copy of the analytical laboratory report is attached.
The sampling locations were the Main Entrance Lobby, 2“* Floor Hallway by Room 213 and 4*
Floor Hallway by Room 403
Wagdi Abdelshahid, Industrial Hygienist and Jimmy Choy, Environmental Technician from
ATC’s New York City office, conducted the sampling consistent with accepted industnal hygiene
practices. The results represent the conditions on the day the samples were collected.
The established regulatoiy values for metals are intended for industnal workplace exposures and
are not generally applicable to office/school settings. There are no standards for these metals in
indoor air in non-industrial situations.
CONFIDENTIAL, CITY_21MC100_003431314
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239717
OCR can misread numbers and units. Confirm readings against the page image before using them.