NYC 9/11 Public Portal Document
Pace Analytical Services, Inc
1700 Elm Street - Suite 200
Minneapolis, MN 55414
'aceAnaIvticar_________ Tel 612-607-1700
Fax. 612- 607-6444
Method 8290 Analysis Results
Client - ATC ASSOCIATES
Client's Sample ID ATC-0827-1M-DX1
Lab Sample ID 103815254
Filename U21010B_13
-i Injected By
Total Amount Extracted
MRO
1.00 m2 Matnx WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/27/2002
ICAL Date 08/06/2002 Received 08/28/2002
CCal Filename(s) U21010A_14 & U21010B_16 Extracted 09/29/2002
Method Blank ID BLANK-2231 Analyzed 10/11/2002 05-30
Native Cone EMPC LRL Internal ng's Percent^
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00230 A 2.3,7,8-TCDF-13C 2.00 79
Total TCDF 0.0076 0 00200 J 2,3,7,8-TCDD-13C 2 00 75
1.2,3,7,8-PeCDF-13C 2.00 85
2,3,7,8-TCDD ND 0 00310 A 2,3,4,7,8-PeCDF-13C 2.00 87
Total TCDD 0.0170 0 00200 1,2,3,7,8-PeCDD-13C 2.00 82 J
1,2,3,4,7,8-HxCDF-13C 2 00 86 4
1,2,3,7,8-PeCDF ND 0 01000 1,2,3,6,7,8-HxCDF-13C 2.00 98 I
2,3,4,7,8-PeCDF ND 0 01000 2,3,4,6,7,8-HxCDF-13C 2 00 92
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2 00 93
1,2,3,4,7,8-HxCDD-13C 2.00 96
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 92
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 90
1,2,3,4,7,8,9-HpCDF-13C 2.00 84
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2 00 84
1,2,3.6,7,8-HxCDF ND 0 01000 OCDD-13C 4.00 63
2,3.4,6.7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1.2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0 01000 1.2,3,7,8,9-HxCDD-13C 2 00 NA
1,2,3,4,7,8-HxCDD ND 0 01000 2,3.7.8-TCDD-37CI4 0.20 79
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0 01000
Total HxCDD ND 0.01000
1,2,3,4,6,7.8-HpCDF ND 0 01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0 01000 Equivalence. 0 000083 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0 02000
OCDD 0 0830 0.02000 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentrabon E = PCDE Interference
A = Oetecbon Limit based on signal-to-noise measurement S = Saturated signal
J = Concentrabon detected is below the calibrabon range ND = Not Detected
B = Less than 10 bmes higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from addibonal analysis * = See Discussion
Report No.... 1061946
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the wntten consent of Pace Analybcal Services, Inc.
CONFIDENTIAL, CITY_21MC100_003431273
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239699