NYC 9/11 Public Portal Document
104 East 25th St 10th Fl
New York New York 10010
WWW ate enviro com
212 353 8280
Fax 212 353 8306
ASSOCIATES INC
August 29 2002
Mr Bernard P Orlan
Director Environmental Health & Safety
New York City Department of Education
28 11 Queens Plaza North
Long Island City NY 11101 4008
Re Air Sampling for Silica
P S 131M
ATC Project No 15 19125 0346
Dear Mr Orlan
ATC Associates Inc (ATC) is pleased to provide this report of the results of air monitoring for
silica containing dust conducted on August 22 2002 at the referenced school The New York
City Department of Education (DOE) requested this monitoring to verify that acceptable indoor
air quality is being maintained
Scope of Work
ATC collected a total of three (3) samples (and one blank) for respirable dust using pre weighed
37mm PVC filters connected to size selective cyclones to remove the larger (non respirable)
particles prior to deposition on the filters All of the samples were collected indoors The
samples were sent to PSC Analytical Services Inc an American Industrial Hygiene Association
accredited laboratory in Reading PA Analysis for silica was performed by x ray diffraction
according to OSHA Method 142 A copy of the analytical report is attached
Tenzin Namgyal and Wagdi Abdelshahid Industrial Hygienists of ATC s New York City office
collected the samples consistent with generally accepted industrial hygiene practices As with all
such sampling there were inherent limitations created by constraints of time operational and
work practice variability variations in air contaminant concentrations and sampling and
analytical accuracy The results of the sampling represent conditions found on the dates the
samples were collected
Results
Samples were obtained in the following locations ist floor Main Lobby 2’1^ floor hallway by
Room 210 and 3*’^ floor hallway by Room 327
The results of all of the samples were below the detection limit for silica (<5 0 micrograms per
sample)
CONFIDENTIAL
SUBJECT TO PROTECTIVE . V ««-21HC100_003«„a,