NYC 9/11 Public Portal Document
104 East 25th St 10th Fl
New York New York 10010
wwwatc enviro com
212 353 8280
Fax 212 353 8306
ASSOCIATES INC
August 28 2002
Mr Bernard P Orlan
Director Environmental Health & Safety
New York City Department of Education
28 11 Queens Plaza North
Long Island City NY 11101 4008
Re Indoor Air Qualify Assessment
Dr Sun Yat Sen School (J H S 13 M)
100 Hester Street
New York, New York 10002
ATC Project No 15-19125-0346
Dear Mr Orlan
ATC Associates Inc (ATC) is pleased to provide this report of indoor air quality (lAQ)
measurements collected on August 22 2002 at the referenced school The New York City
Department of Education (DOE) requested these measurements as part of a program to verify
that acceptable indoor air quality is being maintained
SCOPE OF WORK
ATC conducted this evaluation to assess the basic parameters of temperature relative humidity
carbon dioxide (CO,) and carbon monoxide (CO)
Total volatile organic compounds (TVOCs) and respirable particulates were also measured
Mariana Medinets Environmental Technician of ATC s New York City office conducted the
assessment ATC s findings are based on a visual inspection real time environmental
measurements and conditions present in the school at the time of the assessment
ATC measured temperature, relative humidity COj and CO with a Q Trak® Model 8551
manufactured by TSI, Inc
ATC measured concentrations of respirable particulates (PM2 5) with a Dust Trak® Aerosol
Monitor Model 8520 manufactured by TSI Inc
fl#
ATC measured concentrations of TVOCs using a RAE Systems Inc MiniRAE® photoionization
detector (PID)
The assessment was performed consistent with generally accepted indoor air quality assessment
practices As with all such assessments there were inherent limitations created by constraints of
time operational and work practice variability variations in indoor air quality parameters and
sampling and analytical accuracy