NYC 9/11 Public Portal Document
104 East 25th St,. 10th Fl
New York. New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
ASSOCIATES INC.
August 29, 2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101 -4008
Re: Air Sampling for Silica
P. S. 131M
ATC Project No. 15-19125-0346
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of the results of air monitoring for
silica-containing dust conducted on August 22, 2002, at the referenced school. The New York
City Department of Education (DOE) requested this monitoring to verify that acceptable indoor
air quality is being maintained.
Scope of Work
ATC collected a total of three (3) samples (and one blank) for respirable dust using pre-weighed
37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable)
particles prior to deposition on the filters. All of the samples were collected indoors. The
samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association
accredited laboratory in Reading, PA. Analysis for silica was performed by x-ray diffraction
according to OSHA Method 142. A copy of the analytical report is attached.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office,
collected the samples consistent with generally accepted industrial hygiene practices. As with all
such sampling, there were inherent limitations created by constraints of time, operational and
work practice variability, variations in air contaminant concentrations and sampling and
analytical accuracy. The results of the sampling represent conditions found on the dates the
samples were collected.
Results
Samples were obtained in the following locations: ist floor Main Lobby, 2nd floor hallway by
Room 210 and 3^1 floor hallway by Room 327.
The results of all of the samples were below the detection limit for silica (<5.0 micrograms per
sample).
CONFIDENTIAL, CITY_21MC100_003430901
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239530
OCR can misread numbers and units. Confirm readings against the page image before using them.