September 13, 2002
Mr. Bernard P..Orlan
Director, Environmental Health & Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101-4008
Re: Air Sampling for Silica
P. S. 126M
ATC Project No. 15-19125-0343
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is.pleased to provide this report of the results of air monitoring for
silica-containing dust conducted on August 29, 2002, at the referenced school. The New York 1
City Department of Education (DOE) requested this monitoring prior to the resumption of
classes to verify that acceptable indoor air qualify is being maintained.
Scope of Work
ATC collected a total of five (5) samples (and one blank) for respirable dust using pre-weighed
37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable)
particles prior to deposition on the filters. All of the samples were collected indoors. The
samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association
accredited laboratory in Reading, PA. Analysis for silica was performed by x-ray diffraction
according to OSHA Method 142. A copy of the analytical report is attached.
Wagdi Abdelshahid, Industrial Hygienist and Jimmy Choy, Environmental Technician of ATC’s
New York City office, collected the samples consistent with generally accepted industrial
hygiene practices. As with all such sampling, there were inherent limitations created by
constraints of time, operational and work practice variability, variations in air contaminant
concentrations and sampling and analytical accuracy. The results of the sampling represent
conditions found on the dates the samples were collected.
Results
Samples were obtained in the following locations; pt floor Main Lobby, 2"*^ floor hallway by
Room 235, 3’’’^ floor hallway by Room 317, 4^^ floor hallway by Room 435 and 4th floor
hallway by Room 405.
The results of alTof the samples were below the detection limit for silica (<5 micrograms per
sample).