NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC ASSOCIATES
Client's Sample ID ATC-0826-130M-DX1
Lab Sample ID 103810149
Filename F20928A_13
Injected By JAS
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/26/2002
ICAL Date 09/26/2002 Received 08/28/2002
CCal Filename(5) F20927B_16 & F20928A_16 Extracted 09/21/2002
Method Blank ID BLANK-2193 Analyzed 09/28/2002 22:57
Native Cone EMPC LRL internal ng's Percent,,.
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0035 A 2,3,7,8-TCDF-13C 2.00 76
Total TCDF ND 0.0020 2,3.7.8-TCDD-13C 2.00 75
1.2,3,7,8-PeCDF-13C 2.00 82
2.3.7.8-TCDD ND 0.0047 A 2,3,4.7.8-PeCDF-13C 2.00 80
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 85
1,2.3.4,7,8-HxCDF-13C 2.00 101
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 87
2,3,4.7.8-PeCDF ND 0.0100 2.3,4.6.7.8-HxCDF-13C 2.00 88
Total PeCDF ND 0.0100 1,2,3,7.8,9-HxCDF-13C 2.00 77
1,2,3,4,7,8-HxCDD-13C 2.00 110
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 87
Total PeCDD 0.010 0.0100 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 72
1,2,3,4.7,8,9-HpCDF-13C 2.00 53
1.2.3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 60
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 67 *
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3.7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1.2,3,7,8.9-HxCDD-13C 2.00 NA
1,2.3.4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0,20 75
1,2,3.6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.031 0.0100 J
1,2,3,4,6.7,8-HpCDF 0.013 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8.9-HpCDF ND 0.0100 Equivalence: 0.00095 ng/m2
Total HpCDF 0.027 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.031 0.0100 J
Total HpCDD 0.088 0.0100
OCDF 0.036 0.0200 J
OCDD 0.480 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3.7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 1061865
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITy_21MC100_003430541
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238820