NYC 9/11 Public Portal Document
Pace Analytical Services. Inc.
1700 Elm Street • Suite 200
Minneapolis, MN 55414
'ace Analytical__________ Tel: 612-607-1700
Fax: 612- 607-6444
Method 8290 Analysis Results
Client - ATC ASSOCIATES
Client's Sample ID ATC-0826-130M-DX2
Lab Sample ID 103810156
Filename U20929B_09
Injected By BAL
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/26/2002
ICAL Date 08/06/2002 Received 08/28/2002
CCal Filename(s) U20929B_01 & U20929B_17 Extracted 09/21/2002
Method Blank ID BLANK-2193 Analyzed 09/30/2002 07:17
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 71
Total TCDF ND 0.00200 2,3,7,8-TCDD-13C 2.00 69
1,2,3,7,8-PeCDF-13C 2.00 72
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 70
Total TCDD 0.0060 0.00200 J 1.2,3,7,8-PeCDD-13C 2.00 73
1,2,3.4.7.8-HxCDF-13C 2.00 73
1,2,3,7,8-PeCDF ND 0.01000 1,2,3.6,7.8-HxCDF-13C 2.00 86 s
2,3,4,7.8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 76
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 64
1,2,3,4,7,8-HxCDD-13C 2.00 104
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 76
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 63
1,2,3,4,7,8,9-HpCDF-13C 2.00 46
1.2.3,4.7,8-HxCDF ND 0.01000 1,2,3,4.6,7,8-HpCDD-13C 2.00 73
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 59
2,3.4,6,7,8-HxCDF ND 0.01000
1,2,3.7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8.9-HxCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD ND 0.01000 2,3.7.8-TCDD-37CI4 0.20 72
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence; 0.00025 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0130 0.01000 J
Total HpCDD 0.0250 0.01000 J
OCDF ND 0.02000
OCDD 0.1300 0.02000 B
LRL • Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted Isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J - Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 1061865
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003430435
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238767
OCR can misread numbers and units. Confirm readings against the page image before using them.