Mr. Bernard P. Orlan February 7, 2002
Air Sampling for Silica Page 2
StuvA^esant High School ATC Project No. 15-19125-0246
Sample S6, collected in the 3'^'’ floor Gym contained 0.0135 mg/m’ of silica. The amount of quartz
in this sample was <22%, therefore the PEL for this dust would be:
lOmg/m^ 0.417 mg/m^
22 + 2
The silica concentration in this sample was 0.0135 mg'mg\ which is 3.2% of the calculated PEL.
Sample S7, collected in the 4“' floor Hallway contained 0.0147 mg/m^ of silica. The amount of
quartz in this sample was <24%, therefore the PEL for this dust would be:
10m g/m^ 0.385 mg/m’
24 + 2
The silica concentration in this sample was 0.0147 mg/mg^, which is 3.5% of the calculated PEL.
The OSHA PEL is the only regulatory standard for silica exposure, however it is intended for
occupational exposure in settings such as foundries, sandblasting, rock drilling, etc. The EPA
does not have an ambient-air quality standard for silica.
Silica was not detected in any of the samples collected on January 23’^.
ATC appreciates the opportunity to provide this indoor air quality consultative service to the
BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division