Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-03O1-STY-DX-2
Lab Sample ID 103363743
Filename F20318B_13
Injected By MASS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/01/2002
ICAL Date 01/24/2002 Received 03/05/2002
CCal Filename(s) F20318B_01 &F20318B_17 Extracted 03/12/2002
Method Blank ID BLANK-1505 Analyzed 03/19/2002 01:25
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0020 2,3,7,8-TCDF-13C 2.00 71
Total TCDF 0.0046 0.0020 J 2,3,7.8-TCDD-13C 2.00 67
1,2,3,7,8-PeCDF-13C 2.00 71
2,3,7,8-TCDD ND 0.0020 2,3,4,7,8-PeCDF-13C 2.00 70
Total TCDD 0.0200 0.0020 1,2,3,7,8-PeCDD-13C 2.00 67
1,2,3,4,7.8-HxCDF-13C 2.00 109
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 65
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 85
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 91
1,2,3,4,7,8-HxCDD-13C 2.00 109
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 65
Total PeCDD 0.0290 0.0100 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 74
1,2,3,4,7,8,9-HpCDF-13C 2.00 73
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 83
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 73
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.0120 0.0100 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 0.020 0.0100 I 2,3,7,8-TCDD-37CI4 0.20 75
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.2800 0.0100
1,2,3,4,6,7,8-HpCDF 0.0260 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7.8,9-HpCDF ND 0.0100 Equivalence: 0.0020 ng/m2
Total HpCDF 0.0480 0.0100 J (Using ITE Factors)
1,2,3,4,6,7.8-HpCDD 0.1300 0.0100
Total HpCDD 0.3800 0.0100
OCDF 0.0350 0.0200 J
OCDD 0.4800 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 02-1054702
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003429602
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238281
OCR can misread numbers and units. Confirm readings against the page image before using them.