NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Dioxin analysis results, Pace Analytical, Feb 2002

Machine-extracted title · confidence 90%

Laboratory data for dioxin compounds from wipe samples analyzed by Pace Analytical in early February 2002.

NYC-WTC_000238255
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FES-ia-02 ,1:13 FROM-PACE ANALYTICAL 612-E07-B444 T-543 P.04/05 F-866 1700 Elin Street - Suite 200 Minneapolis, MN 55414

/\^ce Analytical Tel: 612-607-1700 Fay ei 3- fiO7-RAAA Method 8290 Analysis Results Client - ATC Pit;-. WIT-. / '■J ’.■"i; I Client's Sample ID ATC-0123-STY-DX3 Lab Sample ID 103288290 , 'V / Filename U20212B_10 Injected By BAL Total Amount Extracted 1 m2 Matrix WIPE % Moisture NA Dilution NA Dry Weight Extracted NA Collected 01/23/2002 ICAL Date 01/25/2002 Received 01/25/2002 CCal Fi)®name{s) U20212A_11 & U20212B_15 Extracted 02/08/2002 Method Blank ID BLANK’1457 Analyzed 02/13/2002 07:01 Native Cone EMPC LRU Internal ng's Percent Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery 2.3.7,8-TCDF — 0,0031 0.0025 lA 2,3,7,e-TCDF-13C 2.00 89 Total TCDF 0.061 0.0020 2,3,7,8-TCDD-13C 2.00 97 1,2,3,7.8-PeCDF-13C 2.00 96 2,3,7,8-TCDD ND 0.0046 A. 2,3,4,7,8-PeCDF-13C 2.00 92 Total TCDD 0.077 0.0020 12.3,7,8-PeCDD-13C 2.00 113 1,2.3,4,7,8-HxCDF-13C 2.00 113 1,2.3,7,8-PeCDF ND 0,0100 1,2.3,6,7,8-HxCDF-13C 2.00 90 2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 98 Total PeCDF 0.027 0.0100 J 1,2.3,7,8,9-HxCDF-13C 2.00 98 1.2.3.4.7,8-HxCDD-l3C 2.00 122 1,2,3,7,8-PeCDD ND 0.0100 1,2,3.6,7,8-HxCDD-13C 2.00 112 Total PeCDD 0.079 0.0100 1,2,3.4,6,7.8“HpCDF-13C 2.00 112 1,2,3,4,7,8,9-HpCDF-13C 2.00 91 1,2,3,4.7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 100 1,2.3.6.7.8-HxCDF ND 0.0100 OCDD-13C 4.00 74 2,3,4.6,7,B’HxCDF ND 0.0100 1.2,3.7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA Total HxCDF ND 0.0100 1,2.3,7,8,9-HxCDD-13C 2.00 NA 1,2,3,4,7,8-HxCDD ND 0,0100 2.3,7,8-TCDD-37C14 0.20 78 1,2.3,6,7,8-HxCDD ND 0,0100 1,2,3,7,8,0-HxCDD ND 0.0100 Total HxCDD 0,074 0.0100 1,2,3.4,6,7,8-HpCDF 0.020 0.0100 J Total 2,3.7.8-TCDD 1,2,3,4,7,8,9-HpCDF ND 0,0100 Equivalence; 0.00072 ng/m2 Total HpCDF 0.020 0.0100 J (Using ITE Factors) 1.2.3,4,6.7.8-HpCDD 0.033 0.0100 J Total HpCDD 0.066 0,0100 J OCDF ND 0.0200 OCDD 0.190 0.0200 LRL = Lower Reporting Limit Cone - Conesnvation (Totals Include 2,3,7,8-3ub3trtuted isomers) I s Interference EMPC B Estimated Maximum Possible Concentration E s PCDE Interference A = Detection Limit based on sigrtal-to-noiae measurement S = Saturated signal J = Concentration detected is below the calibration range NO = Not Detected B = Less than 10 times higher than method blank level NA = Not Applicable P = Recovery outside of target range NC = Not Calculated Nn = Value obtained from additional analysis ' = See Discussion Report No.... 02-1053443

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC100_003429561 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000238255

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000238255Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238254

Method 8290 analysis results for dioxins from wipe samples processed by Pace Analytical for ATC Associates.

Similar indexed content

Compare copies and versions →