NYC 9/11 Public Portal Document
Appendix A—Test Cleaning
Ambient sampling results do indicate that the source of contamination is disappearing from the
WTC site, since the fires are extinguished and recent sampling results rarely indicate any
elevated levels. Federal, State, and New York City agencies are confident that the methods of
cleaning (e.g., wet wipes, HEPA-vacuums) recommended to residences and commercial
buildings are appropriate. However, it is also known that these methods are not always 100%
effective, and that there will be instances where apartment owners and commercial facilities will
not clean up as recommended. In order to determine an appropriate protocol for dust abatement,
EPA will abate the interior of one building completely. Findings from this abatement will be
used to modify existing recommended cleaning procedures, if necessary.
EPA will obtain background levels for chemicals of concern for New York City or other similar
cities. Chemicals of concern and health screening levels are being determined via EPA’s Indoor
Air Task Force and will likely include asbestos for dust samples and potentially air samples.
Other related materials (e.g. fibrous glass) may be added as well. The Task Force is in the
process of identifying the characteristics of WTC dust. This cleanup along with the ATSDR
study should also help determine whether surrogates can help predict whether other potential
chemicals of concern (e.g., dioxin) are abated to background levels as well.
Crews will complete cleanup of a small building within close proximity (e.g., within 2 to 4
blocks) to the WTC. New York City’s Office of Emergency Management (NYC OEM) is
identifying a small building (e g. 20 units) with a mix of residential and commercial occupants.
NYC OEM is also working to identify a building with varying levels of dust contamination.
Ideally, some areas will have never been abated, while other areas will have partial or complete
abatement according to recommended procedures. This will allow EPA to address concerns from
the majority of the conditions in buildings within the affected WTC perimeter.
Complete Abatement: For use in heavily contaminated areas. The process will occur in 3 stages:
setup, cleanup, and tear down. Setup involves videotaping, determining conditions indigenous to
the building that will affect sample analyses, moving furniture, and establishing negative
pressure using blowers and vizqueen. Cleanup includes HEPA vacuuming carpeting, furniture,
drapes and wet-moping hard surfaces such as wood floors and counter tops. The best procedures
for cleaning up porous materials such as upholstery, furniture, and carpets to background levels
will be established. Tear down includes post cleanup sampling and analysis, and removal of
cleaning equipment and setup materials.
Recommended Procedures: For use in less contaminated areas. The process used will follow the
wet mopping and HEPA vacuum procedures recommended to building tenants and occupants.
Analysis procedures for asbestos and fibrous glass may include: Phase Contract Microscopy
(PCM) for air only, Polarized Light Microscopy (PLM) for dust only, Transmission Electron
Microscopy (TEM), and Scanning Electron Microscopy (SEM). Other analyses may include:
High Resolution/Mass Spectrometer (HR/MS) for dioxin and PCBs; Inductively Coupled Plasma
3 3/25/02
CITY_21MC1OO_O13378763
NYC-WTC_000238035
OCR can misread numbers and units. Confirm readings against the page image before using them.