Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC ASSOCIATES INC. TEM ANALYSIS
LAE GROUP ft; 5741 - 10/23/01
Lab Sample No. 61970 Filter Type MCE 25 mm Operator
Client Spl. No. 11-lS Filter Area 335 mm^2 /\
r-'-) Instrument I.D. EM 10 CRX Grid I.D. S Disk No.
Screen Magnification 16,400X (GO) Area 0.01124 iimi~2 Comments
Acc. Voltage SO kV No. GO to be Analysed _4 ( 3.147 Struct. Corspd. Co 70 s/mm^2.)
Length I.D. of Structure EDS
GO. Structure Structure Type N or
(Nonasb.
No Coord. No. >0.5 um
F B C M < 5 um Sum Chrys. Amphibole Nonasb. Ambig./ND Elements)
4
Pz.
7
¥
Photo No. (from 1 in 5 as lestos- Identify all atructures using EDS Check diffraction for asbestos store all unrepeated spectra
containing samples) Grid acceptance:). _atructurea up to TOs/^n (1st 4)
<50% undissolved filterr overlapped or folded
Struct. = > O.Sum & > 5:1 Aspect Ratio
<iOX particulate coverage >5035 coverage Totals
Ns Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares
^s Positive diffraction pattern properties conforming
<5% holes or opaque areas___________ _____________ F B C M > Sum
to laboratory identification criteria observed. 'Unuaed portion
Por ehryaoUle: 0.73nm spaeinc for (020) roflecUonx, of fitter Chrysotile
Q.Oanm spacing for the layer line repeat, streaking -Avoided portion
LJ of (no) and (100) reflecUena. of filler
Por amphiboles: O.S3nm layer line repeat, and approx. Portion of filter (Zmm wide)
3.5 ratio of non-twinned layer line spot spacing to subject to
examination
Amphibole
layer line repeat distance (0.93nm).
\/s EOS spectrum conforming to laboratory
identification criteria observed. AMPHIBOLES Ambiguous
Ps Single Fiber (1-3 Intersections = 1-3 fibers) Amosite
Be Bundle (>3 fibers <1 fiber diameter apart)
C= Cluater (>3 interaectione)
asmm fllUr Crocidolite Non-asbestos
- .. ■—i Stopping Rules: 1------
Us Matrix Anthophyllite
NSD= No Structures Detected >30 s/G.O. or In lat 4 G.O. Tremolite
Actinolite Non-Identified
L\Dj»TA\PBIVATE\MJKEC\CADDVSM3 9/22/S8
NYC-WTC_000237487
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000237487Source: NYC Law Department, mirrored locally
Technical data sheet recording transmission electron microscopy parameters and structural identification for asbestos samples analyzed in September 2001.
Technical data sheet recording transmission electron microscopy parameters and structural identification for asbestos samples analyzed in September 2001.
Technical data sheet recording transmission electron microscopy measurements and structural identification for asbestos fiber samples from a school site.
Technical data sheet recording transmission electron microscopy parameters and structural identification for asbestos samples analyzed in September 2001.
Technical data sheet recording transmission electron microscopy parameters and structural identification for asbestos samples analyzed in September 2001.
Technical data sheet recording transmission electron microscopy parameters and structural identification for asbestos samples analyzed in September 2001.
Technical data sheet recording transmission electron microscopy parameters and structural identification for asbestos samples analyzed in September 2001.