NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos air sample analysis, 40 Rector Street, Oct 2001

Machine-extracted title · confidence 95%

Laboratory report documenting asbestos fiber analysis by TEM for an air sample from 40 Rector Street collected on October 23, 2001.

NYC-WTC_000237465
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/23/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) ) With Fiber Identification by Selected-Area Electron Diffraction (SASD) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

I ; j Sample Identification Analysis Parameters

I TEM Sample No.: 5741 - 62026 I I Project/Site; 40 Rector Street, 40 Rector St., Ifif, NY Floors 1-12, 14, 15, 19 Date Received: 10/23/01 Grid Openings Analyzed;_ 4

Project Sample No.: 67-4 Average Grid Opening: 106.00 um

Air Voluine: 1800 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 2S mm diam.. Pore Size; 0.45 um TUialytical Sensitivity: 22.2 s/Tnni2 Effective Area; 385 mm2 0.0048 s/cc

FIBROUS PARTICULATES ANALYZED Nutnber Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ■a Sum Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

.J Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A

No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

NYC-WTC_000237465

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000237465Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →