NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
.J New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/23/01
’ ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
-A with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method; AHERA Pinal Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52. No. 210, October 30, 1987
J Sample Identification Analysis Parameters
—1 Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.: S741 - 61985
Floors ltl2jX4,15,W
Date Received; 10/23/01 Grid Openings Analyzed:__ 4
Project Sample No.; 26-11 Average Grid Opening: 106.00 urn
Air Volume; 1840 liters Total Area Analyzed
Filter Type: MCE 25 mmdiam.. Pore Size; 0.45 um Analytical Sensitivity:22;2 s/nim2
Effective Area; 385 mm2 0.0047 s/cc
FIBROUS PARTTCULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. > = 5um Struct/mm2 Struct/cc nqm/mS
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
'■■'I
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
lA Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237433
OCR can misread numbers and units. Confirm readings against the page image before using them.