NYC 9/11 Public Portal Document
r I
■■.. J
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, ERA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification AnalysisParamet^rs
Project/Site: 40^ector Street.^NY,Jjy TEM Sample No.: 5729 - 61861
Floors 16-18
Date Received: 10/19/01 Grid Openings Analyzed; 6
Project Sample No.; 16 Average Grid Opening; 106,00 urn
Air Volume; 1300 liters Total Area Analyzed; 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 14.8 3/mm2
Effective Area: 385 mm2 0,0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct, Filter Air
-ers Bundles Clusters Stiruct. Struct >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
' ' Non-asbestos fiber i.d. (EDS/SAED): None detected
•J Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
/■"l
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237392
OCR can misread numbers and units. Confirm readings against the page image before using them.